Description:
The PDU is used for distributing 24V DC power to intercom stations. It distributes power to up to18 stations. These are divided into 4 groups, each protected by its own fuse.
The PDU has two power inputs: main and battery, and there is a summing diode for each fuse group.
Specifications:
- 24V DC operation only
- Input max 10A
- 18 power outputs
- Output max 1A
- 4 fused groups
- 2 inputs: main and battery
- Build in summing diode
 